§ 86-294. Lighting and maintenance required.  


Latest version.
  • Any parking lots or garages located within the downtown master plan area must provide adequate lighting between the hours of sunset and dawn. Such lighting shall comply with the lux and candle power requirements contained in Table 1 which is attached to this division as Exhibit "A." Such lots or garages shall be regularly maintained so that they appear clean and free from trash or debris at all times.

    (Ord. No. 3689-03, § 1, 10-14-2003)

    EXHIBIT "A"

    RECOMMENDED MAINTAINED ILLUMINANCE VALUES FOR PARKING LOTS

    Unit Enhanced Security
    Minimum horizontal illuminance on floor Lux 5
    FC 0.5
    Uniformity ratio, maximum to minimum 15:1
    Minimum vertical illuminance at five feet above floor Lux 2.5
    FC 0.25

     

    RECOMMENDED MAINTAINED ILLUMINANCE VALUES FOR PARKING GARAGES

    Minimum Horizontal Illuminance on Floor Maximum/Minimum Horizontal Uniformity Minimum Vertical Illuminance at Five Feet
    Lux Footcandles Ratio Lux Footcandles
    Basic 10 1 10:1 5 0.5
    Ramps
    Day 20 2 10:1 10 1
    Night 10 1 10:1 5 0.5
    Entrance Area
    Day 500 50 250 25
    Night 10 1 10:1 5 0.5
    Stairways 20 2 10 1

     

    All parking lot and garage lighting shall meet UL® lighting standards.

    Source: Illuminating Engineering Society of North America, RP-20-98, Lighting for Parking Facilities (New York: IES, 1998).

(Ord. No. 3689-03, Exh. A, 10-14-2003)